195 matches for the search term(s) "novus"

Showing 1 to 20 of 195 results
  
RTD sensor 316 SS 6x250mm, 1/2"BSP w/ aluminum head, -50~300 °C
  • Temperature Sensor
  • Probe Size: 6x250mm
   Weight: 4200637
N322 Pt100 with RS485 Electronic Thermostat - Pt100 input - 2 relays output; Digital temperature controller for heating and refrigeration purposes with 2 independent setpoints. It has Pt1000, thermistor NTC, PTC or J thermocouples inputs available.
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C )
  • IP65 enclosure frontal protection Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive) and relay SPST-NA: 3 A / 250 Vca
  • Resolution: 0,1 °C from -19,9 to 199,9 °C Accuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis Sampling: 1,5 per second
  • Working temperature: 0 to 50 °C
  • Power supply: 100-240 Vac/dc (internal) or 12-30 Vdc/ac
  • Digital communication via RS485 with Modbus RTU protocol(optional)
  • Dimensions: 75 x 33 x 75 mm
  • RS 485: Y
  • 24 VDC: N
   Weight: 4200616
N1500 Universal Process Meter with 2 relays 96x48mm with RS485 96x48mm; The N1500 series of Universal Process Indicators are high performance instruments used for monitoring analog signals in the vast majority of industrial and laboratory processes. Configuration from the front panel is fast and easy, accepting thermocouples, Pt100 and 4-20 ...
  • Double display – 8 digits PV+SP and PV + timer indications Universal input: thermocouples, Pt100, mV, V and mA optional.
  • Personalized linearization 3 output channels: 1 pulse and 2 relays (10 A relay optional) 2 alarms with configurable functions
  • •Digital input for special functions Second output control for servo positionersPID
  • Auto-tuning Soft start Ramp function
  • 20 programs each with 9 segments Datalogger with real time watch function and capacity for 32.000 records
  • Programmable timer Adjustable time base in seconds or minutes
  • Access protection by password Factory calibration can be restored• Optional serial communication
  • Carries USB for controller configuration and data acquisition Complimentary configuration software
  • 24 VDC: N
  • RS 485: Y
   Weight: 4200616
HUBA 692 Differential Pressure, 4-20mA out, IP65 connector: 0...0.3 bar ; The 692 series of differential pressure transmitters use unique ceramic technology to accurately measure from 0 to 0.1 bar up to 0 to 6 bar differential and yet withstanding high one-side overloads.
  • Ranges: 0 to 0.1 bar and up to 0 to 6 bar Working temperature: -15 to 80°C
  • Media material: ceramic and 1.4305 stainless steel (AISI 303)
  • Accuracy: 0.5% FS including hysteresis, linearity and repeatability
  • Pressure connection: 1/8" thread or push-on spigot
  • System pressure: 25 bar to pressure range 10 bar. 50 for pressure range 25 bar
  • Rupture pressure: 1.5X system pressure Electrical connector: DIN 43650-A, IP65 or cable gland with 1.5m cable
  • Output: two-wire 4-20mA. Other signals under request Electromagnetic compatibility: CE conformity to EC directive 89/336
  • Power supply: 11 to 33Vdc Dimensions: Ø 45 x 89mm
  • Pressure Range: .3 Bar
  • Pressure Type: Differential
   Weight: 4200607
The N321 temperature controller are used to measure, indicate and control temperature in many different systems. Accepts 4 sensors types: Pt100, Pt1000, NTC or Thermocouple J. The user can program the control action according to the application: direct action (refrigeration) or reverse action (heating). The internal 10 A relay can ...
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C)
  • IP65 enclosure frontal protection
  • Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive)
  • Resolution: 0,1 °C from -19,9 to 199,9 °C
  • Accuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis
  • Sampling: 1,5 per second
  • Working temperature: 0 to 50 °C
  • Power supply: 100-240 Vac (internal) or 12-24 Vac/dc
  • Digital comunication via RS485 with Modbus RTU protocol (optional)
  • Dimensions: 75 x 33 x 75mm
  • RS 485: N
  • 24 VDC: N
   Weight: 4200545
N321 Pt100 12~24Vdc Electronic Thermostat, Pt100 input, 1 relay output; The N321 temperature controller are used to measure, indicate and control temperature in many different systems. Accepts 4 sensors types: Pt100, Pt1000, NTC or Thermocouple J. The user can program the control action according to the application: direct action (refrigeration) ...
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C)
  • IP65 enclosure frontal protection
  • Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive)+
  • Resolution: 0,1 °C from -19,9 to 199,9 °C
  • Accuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis
  • Sampling: 1,5 per second
  • RS 485: N
  • 24 VDC: Y
   Weight: 4200545
N321 NTC Electronic Thermostat, NTC thermistor input, 1 relay output; The N321 temperature controller are used to measure, indicate and control temperature in many different systems. Accepts 4 sensors types: Pt100, Pt1000, NTC or Thermocouple J. The user can program the control action according to the application: direct action (refrigeration) ...
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C)
  • IP65 enclosure frontal protection Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive)
  • Resolution: 0,1 °C from -19,9 to 199,9 °CAccuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis
  • Sampling: 1,5 per second Working temperature: 0 to 50 °C
  • Working temperature: 0 to 50 °C
  • Power supply: 100-240 Vac (internal) or 12-24 Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: N
  • RS 485: N
   Weight: 4200545
N321 NTC 12~24Vdc Electronic Thermostat, NTC thermistor input, 1 relay output; The N321 temperature controller are used to measure, indicate and control temperature in many different systems. Accepts 4 sensors types: Pt100, Pt1000, NTC or Thermocouple J. The user can program the control action according to the application: direct action ...
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C)
  • IP65 enclosure frontal protection Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive)
  • Resolution: 0,1 °C from -19,9 to 199,9 °CAccuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis
  • Sampling: 1,5 per second Working temperature: 0 to 50 °C
  • Working temperature: 0 to 50 °C
  • Power supply: 100-240 Vac (internal) or 12-24 Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • RS 485: N
  • 24 VDC: Y
   Weight: 4200545
N321 J/K/T Electronic Thermostat, J/K/T thermocouple input, 1 relay output ; The N321 temperature controller are used to measure, indicate and control temperature in many different systems. Accepts 4 sensors types: Pt100, Pt1000, NTC or Thermocouple J. The user can program the control action according to the application: direct action ...
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C)
  • IP65 enclosure frontal protection Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive)
  • Resolution: 0,1 °C from -19,9 to 199,9 °CAccuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis
  • Sampling: 1,5 per second Working temperature: 0 to 50 °C
  • Working temperature: 0 to 50 °C
  • Power supply: 100-240 Vac (internal) or 12-24 Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • RS 485: N
  • 24 VDC: N
   Weight: 4200545
N321 J/K/T 12~24Vdc Electronic Thermostat, J/K/T thermocouple input, 1 relay out; The N321 temperature controller are used to measure, indicate and control temperature in many different systems. Accepts 4 sensors types: Pt100, Pt1000, NTC or Thermocouple J. The user can program the control action according to the application: direct action ...
  • Sensor input: Pt100 (-50 to 300 °C), Pt1000 (-200 to 530 ºC), Thermocouple J (0 to 600 °C) or thermistor (-30 to +105°C)
  • IP65 enclosure frontal protection Output: Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive)
  • Resolution: 0,1 °C from -19,9 to 199,9 °CAccuracy: ± 0,5 °C / °F ±1 digit (Pt100 / Pt1000 / Thermistor) and ±2 °C for Thermocouple
  • Adjustable hysteresis
  • Sampling: 1,5 per second Working temperature: 0 to 50 °C
  • Working temperature: 0 to 50 °C
  • Power supply: 100-240 Vac (internal) or 12-24 Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: Y
  • RS 485: N
   Weight: 4200545
N321R Pt100 defrost Electronic Thermostat , Pt100 input, 1 relay output; The N321R is a temperature controller dedicated to applications in refrigeration. The defrost cycle is accomplished by turning off the compressor at time intervals chosen by the user. Pt100, Pt1000 and thermistor sensors inputs available. Adjust for ON and ...
  • Sensor input: Pt100 (-50 to 300ºC), Pt1000 (-200 to 530°C) or thermistor (-30 to +105°C)IP65 enclosure frontal protection
  • Display indication does not change during defrost cycles Minimum ON and OFF durations accessed by the user
  • Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive) (up to 1HP compressors)
  • Resolution: 0,1°C from -19,9 to 199,9°CAccuracy: ± 0,5°C/°F ±1 digit
  • Adjustable hysteresis Sampling: 1,5 per second
  • Working temperature: 0 to 50°C
  • Power supply: 85-250Vac (internal) or 12-24Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: N
  • RS 485: N
   Weight: 4200545
N321R Pt100 defrost 12~24Vdc Electr. Thermostat , Pt100 input, 1 relay output; The N321R is a temperature controller dedicated to applications in refrigeration. The defrost cycle is accomplished by turning off the compressor at time intervals chosen by the user. Pt100, Pt1000 and thermistor sensors inputs available. Adjust for ON ...
  • Sensor input: Pt100 (-50 to 300ºC), Pt1000 (-200 to 530°C) or thermistor (-30 to +105°C)IP65 enclosure frontal protection
  • Display indication does not change during defrost cycles Minimum ON and OFF durations accessed by the user
  • Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive) (up to 1HP compressors)
  • Resolution: 0,1°C from -19,9 to 199,9°CAccuracy: ± 0,5°C/°F ±1 digit
  • Adjustable hysteresis Sampling: 1,5 per second
  • Working temperature: 0 to 50°C
  • Power supply: 85-250Vac (internal) or 12-24Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: Y
  • RS 485: N
   Weight: 4200545
N321R NTC defrost Electr. Thermostat NTC input, 1 relay output; The N321R is a temperature controller dedicated to applications in refrigeration. The defrost cycle is accomplished by turning off the compressor at time intervals chosen by the user. Pt100, Pt1000 and thermistor sensors inputs available. Adjust for ON and OFF ...
  • Sensor input: Pt100 (-50 to 300ºC), Pt1000 (-200 to 530°C) or thermistor (-30 to +105°C)IP65 enclosure frontal protection
  • Display indication does not change during defrost cycles Minimum ON and OFF durations accessed by the user
  • Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive) (up to 1HP compressors)
  • Resolution: 0,1°C from -19,9 to 199,9°CAccuracy: ± 0,5°C/°F ±1 digit
  • Adjustable hysteresis Sampling: 1,5 per second
  • Working temperature: 0 to 50°C
  • Power supply: 85-250Vac (internal) or 12-24Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: N
  • RS 485: N
   Weight: 4200545
N321R NTC LVD "Low Voltage Detector" ; The N321R is a temperature controller dedicated to applications in refrigeration. The defrost cycle is accomplished by turning off the compressor at time intervals chosen by the user. Pt100, Pt1000 and thermistor sensors inputs available. Adjust for ON and OFF durations. Auto defrost ...
  • Sensor input: Pt100 (-50 to 300ºC), Pt1000 (-200 to 530°C) or thermistor (-30 to +105°C)IP65 enclosure frontal protection
  • Display indication does not change during defrost cycles Minimum ON and OFF durations accessed by the user
  • Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive) (up to 1HP compressors)
  • Resolution: 0,1°C from -19,9 to 199,9°CAccuracy: ± 0,5°C/°F ±1 digit
  • Adjustable hysteresis Sampling: 1,5 per second
  • Working temperature: 0 to 50°C
  • Power supply: 85-250Vac (internal) or 12-24Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: N
  • RS 485: N
   Weight: 4200545
N321R NTC defrost 12~24Vdc Electr. Thermostat NTC input, 1 relay output; The N321R is a temperature controller dedicated to applications in refrigeration. The defrost cycle is accomplished by turning off the compressor at time intervals chosen by the user. Pt100, Pt1000 and thermistor sensors inputs available. Adjust for ON and ...
  • Sensor input: Pt100 (-50 to 300ºC), Pt1000 (-200 to 530°C) or thermistor (-30 to +105°C)IP65 enclosure frontal protection
  • Display indication does not change during defrost cycles Minimum ON and OFF durations accessed by the user
  • Relay SPDT: 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resisitive) (up to 1HP compressors)
  • Resolution: 0,1°C from -19,9 to 199,9°CAccuracy: ± 0,5°C/°F ±1 digit
  • Adjustable hysteresis Sampling: 1,5 per second
  • Working temperature: 0 to 50°C
  • Power supply: 85-250Vac (internal) or 12-24Vac/dc
  • Digital communication via RS485 with Modbus RTU protocol (optional)
  • 24 VDC: Y
  • RS 485: N
   Weight: 4200545
N321S NTC Differential Temperature Controller for Solar Heating 2 sensors; The N321S is a controller intended for solar water heating applications. It controls the water circulation system based on the difference of temperature between the solar collector and the storage tank (or swimming pool).The instrument contains two NTC-type temperature sensors ...
  • NTC Thermistor: 10 kΩ @ 25 °C, range: -30 to +105°C (-22 to 221 °F), Accuracy: 0,6 °C (1,1 ºF)
  • Sensor interchangeability: 0,75 ºC (1,35 ºF)
  • Measurement Resolution: 0,1º from –19.9 to 119.9º
  • Output: Relay SPDT, 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resistive)
  • POWER SUPPLY: 100 to 240 Vac/dc ±10%
  • Optionally: 12 to 30 Vdc/ac
  • Mains Frequency: 50~60 Hz
  • Power Consumption: 5 VA
  • RS 485: N
  • 24 VDC: N
   Weight: 4200545
N321S 12~24 Vdc Differential Temperature Controller for Solar Heating 2 sensors; The N321S is a controller intended for solar water heating applications. It controls the water circulation system based on the difference of temperature between the solar collector and the storage tank (or swimming pool).The instrument contains two NTC-type temperature ...
  • NTC Thermistor: 10 kΩ @ 25 °C, range: -30 to +105°C (-22 to 221 °F), Accuracy: 0,6 °C (1,1 ºF)
  • Sensor interchangeability: 0,75 ºC (1,35 ºF)
  • Measurement Resolution: 0,1º from –19.9 to 119.9º
  • Output: Relay SPDT, 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resistive)
  • POWER SUPPLY: 100 to 240 Vac/dc ±10%
  • Optionally: 12 to 30 Vdc/ac
  • Mains Frequency: 50~60 Hz
  • Power Consumption: 5 VA
  • RS 485: N
  • 24 VDC: Y
   Weight: 4200545
Showing 1 to 20 of 195 results